MF - Monitor Sample Schedule

For intermittent monitors, this transaction defines the expected time periods between samples.

Rules

Monitor Sampling Schedule is required for PM10 and PM2.5 monitors. Error Messages:

The Required Collection Frequency assignment for a production monitor cannot be changed, (i.e., updated or deleted), in a manner that would leave any portion of that monitor’s sample periods since 1987-07-01 without a required collection frequency.

A Seasonal Required Collection Frequency assignment, (i.e., where RCF Code is “S”), requires at least twelve Monthly Collection Frequencies for a PM2.5 monitor and a seasonal or random Required Collection Frequency assignment, (.i.e., where RCF Code is “8”, “9”, or “S”), requires at least one Monthly Collection Frequency for a non-PM2.5 monitor.

Examples:

MF transaction in default mode
MF|I|06|001|0007|88101|3|1|20110101||||||||||||||0
MF transaction in Tribal mode
MF|I|TT|614|7004|81102|1|3|20020701||||||||||||||0

Format

MF - Sample Schedule transaction format

Seq.

Name

Description

Formatting Rules

Required

Key

1

Transaction Type

Monitor Sampling Schedule transaction identifier.

Must = MF

Always

2

Action Indicator

Indicator for Insert, Update, or Delete action.

Must = I, U, or D

Always

3

State Code / Tribal Indicator

The FIPS state code of the monitor, or “TT” to indicate that the next field on the transaction is a Tribal code.

Must exist in STATES Reference Table or be ‘TT’ for Tribal Site

Always

Y

4

County Code / Tribal Code

The FIPS County Code of the site. If the previous field on the transaction contains “TT”, then the Tribal Code of the site.

Must exist in COUNTIES (for state) or TRIBAL_AREAS Reference table

Always

Y

5

Site Number

Four digit number to uniquely identify site in county and/or tribe.

Must exist in SITES table with {State Code, county Code} or Tribal Code

Always

Y

6

Parameter Code

The AQS parameter code assigned to the monitor in AQS.

Must exist in PARAMETERS reference table.

Always

Y

7

POC

Parameter Occurrence Code: One or two digit number identifying a specific monitor for a parameter at the site.

Must exist in MONITOR table for non-Insert actions.

Always

Y

8

Required Collection Frequency Code

Code representing the sample collection freqency for PAMS and PM2.5 and PM10

Must exist in COLLECTION FREQUENCIES reference table.

Always

Y

9

Required Collection Frequency Begin Date

The date on which the required collection frequency (RCF) went into effect.

YYYYMMDD.

Always

Y

10

Required Collection Frequency End Date

The date on which the required collection frequency (RCF) ceased being in effect.

YYYYMMDD.

No

11

Monthly Required Collection Frequency - Jan

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

12

Monthly Required Collection Frequency - Feb

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

13

Monthly Required Collection Frequency - Mar

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

14

Monthly Required Collection Frequency - Apr

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

15

Monthly Required Collection Frequency - May

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

16

Monthly Required Collection Frequency - Jun

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

17

Monthly Required Collection Frequency - Jul

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

18

Monthly Required Collection Frequency - Aug

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

19

Monthly Required Collection Frequency - Sep

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

20

Monthly Required Collection Frequency - Oct

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

21

Monthly Required Collection Frequency - Nov

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

22

Monthly Required Collection Frequency - Dec

Specifies the collection frequency required within an indicated month.

Must exist in COLLECTION FREQUENCIES reference table.

No

23

Offest

Specifies the number of days this monitor samples after the standard scheduled day.

Ineger.

No